EMD-FL-PF-400 – Monitoring Relay 2885809

In Stock
8,089.00
In Stock
Other people want this. 3 people have this in their carts right now.

Description

Phoenix Contact Monitoring relay for load monitoring (cos ϕ = 0,1…1) in 1- and 3-phase networks, underload, overload, window, error memory, wide range power supply unit, 2 changeover contacts

 


Notes
Utilization restriction
EMC note EMC: class A product, see manufacturer’s declaration in the download area

Product properties
Product type Load monitoring relay
Operating mode 100% operating factor
Mechanical service life approx. 2x 107 cycles
Insulation characteristics
Insulation Basic insulation
Overvoltage category III
Pollution degree 2

Electrical properties
Service life electrical 2x 105 cycles at ohmic load, 1000 VA
Mains type 1 and 3-phase
Rated insulation voltage 300 V
Rated surge voltage 4 kV
Supply
Supply voltage range 24 V AC … 240 V AC -15 % … +10 %
24 V DC … 240 V DC (-20 % … +25 %)
Type of supply voltage AC/DC
Nominal power consumption 4.5 VA (1.5 W)

Input data
Input name Measuring input
Measured value AC sine (10 … 100 Hz)
Nominal input voltage UN 3 N ~ 415/240 V
Input voltage range 40 V AC … 415 V AC (1(N) ~, single-phase load)
40 V AC … 415 V AC (3(N) ~, 3-phase load)
Maximum input voltage 3 N ~ 500/289 V
Input current range 0.5 A … 10 A (Connection terminal blocks: L1i and L1k)
Overload capacity 12 A permanent
Input resistance of voltage input ≥ 1 MΩ
Input resistance current input 5 mΩ
Min. switching threshold cos φ 0.1 … 0.99
Max. switching threshold cos φ 0.2 … 1
Frequency range 48 Hz … 400 Hz
Maximum temperature coefficient ≤ 0.1 %/K
Setting range for response delay 0.1 s … 40 s
Setting range for starting delay 1 s … 100 s
Function Underload
Overload
Window
Error memory
Basic accuracy ± 5 % (at cos φ = 0.8)
Setting accuracy ≤ 5 % (at cos φ = 0.8)
Repeat accuracy ± 1.8 %
Recovery time 500 ms

Output data
Switching
Contact switching type 2 floating changeover contacts
Maximum switching voltage 250 V AC (in acc. with IEC 60664-1)
Interrupting rating (ohmic load) max. 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
Output fuse 5 A (fast-blow)

Connection data
Connection method Screw connection
Stripping length 8 mm
Conductor cross section rigid 0.5 mm² … 2.5 mm²
Conductor cross section flexible 0.25 mm² … 2.5 mm²
Conductor cross section AWG 20 … 14

Dimensions
Width 22.5 mm
Height 90 mm
Depth 113 mm

Material specifications
Color green (RAL 6021)
Housing insulation material Polyamide PA, self-extinguishing